Technical data ProTec 100
Impact test
Acceptance test: | TB 21 + TB 41 |
Test date: | 03.05.2011 |
Containment level: | T1/T 3 |
Test location: | TÜV Süd, Munich |
Minimum installation length: | 137 m |
Ground anchoring: | no |
System description
Material: | steel and concrete |
Height: | 0,56 m |
Element length: | 6,00 m |
Structural width: | 0,25 m |
Planning width: | 0,12 m |
Weight per m: | 124 kg |
Test conditions
Test vehicle: | car 1,3 t; impact angle 8°; 80 km/h |
truck 10 t; impact angle 8°; 70 km/h |
Test results
T3: dyn. deflection 0,55 m + structural width 0,25 m = 0,8 m (corresponds to effective range W2) |
ASI value: 0,2 (A) |
T1: dyn. deflection 0,25 m + structural width 0,25 m = 0,5 m (corresponds to effective range W1) |
ASI value: 0,2 (A) |
Test reports
Test reports ProTec 100: BASt 2011 7E 56 |
Test reports reflektor element: BASt V4-64/2010 |